5.6 MODULE 6 - SETPOINT (ALARM) PARAMETERS ()
PARAMETER MENU
FLASH
rEv
YES
LAtC2
rEv
 to  sec
 to  sec
1 to 65000
-19999 to 99999
nor
OFF
 - SETPOINT ANNUNCIATORS
NO
 - STANDBY OPERATION
LAtC1
AUto
 - RESET ACTION
nor
 - OUTPUT LOGIC
 - OFF TIME DELAY
 - ON TIME DELAY
 - SETPOINT HYSTERESIS
 - SETPOINT VALUE
Modules 6, 7, and 8 are accessible only with the appropriate plug-in cards installed. A quick overview of Modules 6 & 8
is listed below. Refer to the corresponding plug-in card bulletin for a more detailed explanation of each parameter selection.
Repeat programming for each setpoint.
Enter the action for the selected setpoint (alarm output).
See Setpoint Alarm Figures in the Setpoint Card Literature for a visual detail
of each action.
NO = No Setpoint Action
!&% = Absolute high, with balanced hysteresis
! = Absolute low, with balanced hysteresis
&% = Absolute high, with unbalanced hysteresis
 = Absolute low, with unbalanced hysteresis
&% = Deviation low, with unbalanced hysteresis
*
 = Deviation high, with unbalanced hysteresis
*
! = Outside band, with unbalanced hysteresis
*
!%# = Inside band, with unbalanced hysteresis
*
 = Lower Totalizer absolute high, unbalance hysteresis
**
&% = Upper Totalizer absolute high, unbalance hysteresis
**
* Setpoint 2 or Setpoint 4 deviation and band action setpoints are relative to
the value of setpoint 1 or Setpoint 3 respectively. It is not possible to configure
setpoint 1 or 3 as deviation or band actions. It is possible to use setpoint 1 or 3
for an absolute action, while its value is being used for deviation or band.
** These modes only appear, and are the only modes that appear, when the
setpoint assignment # is set to . The lower Totalizer action, ,
allows setpoints to function off of the lower 5 digits of the Totalizer. The upper
Totalizer action, '% , allows setpoints to function off of the upper 4 digits
of the Totalizer. To obtain absolute low alarms for the Totalizer, program the
 or '% output logic as reverse.
The parameters listed below are different from those listed in the Setpoint
Card Literature. Use the Refer to Setpoint Option Card Literature for all other
setpoint parameters.
SETPOINT ASSIGNMENT


NONE A-rEL A-Abs b-rEL
b-AbS CALC tot
Selects the meter value that is used to trigger the Setpoint Alarm. The -rEL
settings cause the setpoint to trigger off of the relative (net) input value.
The -AbS settings cause the setpoint to trigger off of the absolute (gross)
input value.
SETPOINT ACTION


NO Ab-HI Ab-LO AU-HI
AU-LO
dE-HI
*
dE-LO
*
bANd
*
bNdIn
totLo
**
tothI
**
SP-4SP-2
SP-3SP-1


SELECT SETPOINT
Select a setpoint (alarm output) to open the remaining module menu. (The
#” in the following parameters will reflect the chosen setpoint number.) After
the chosen setpoint is programmed, the display will default to  . Select
the next setpoint to be programmed and continue the sequence for each setpoint.
Pressing PAR at   will exit Module 6.
NO